Victron Autotransformer 120/240VAC-32A

An Autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention.

Specifications:

  • Input/output voltage 120 / 240V
  • Input circuit breaker 32A, two pole 
  • Frequency 50/60Hz
  • Maximum 240 V feed through current 32A
  • Neutral current, 30 min 32A (3800 VA)
  • Neutral current, continuous 28A @ 40ºC/100ºF
  • Transformer type Toroidal
  • Enclosure Aluminium
  • Input circuit breaker yes
  • Protection category IP21
  • Safety EN 60076
  • Weight 12,5 kg 
  • Dimensions (h x w x d) 375 x 214 x 110 mm

 

Features:

The Autotransformer: for step up, step down and split phase balancing

An autotransformer can be used for step up, step down and split phase output balancing purposes. While the step up and step down functions are fairly straightforward, split phase output balancing may require some more attention. Consider for example a 30A 120/240V split phase supply. The supply could be the grid, a generator or two stacked inverters. Some of the loads connected are 240V, others are 120V. On each 120V leg the load should not exceed 30A. The problem is that as soon as 120V loads are connected, the two legs will show a different current. This is because the 120V loads on the two legs will never be balanced. A 120V 1200W hairdryer, for example, will draw 10A from one leg. A 120V washing machine could even draw in excess of 20A from one leg. Between the two legs the difference in current, or current unbalance, will therefore often be 20A or more. This means that the 30A supply will not be used up to its full potential. By the time one leg draws 30A, the other leg may be drawing no more than 10A, and increasing the 240V load, for example, will result in an overload of one leg while the other leg still has spare capacity. Theoretically, the total power that can be drawn from a 30A 120/240V supply is 30 x 240 = 7,2 kVA. In case of 20A unbalance, the practical maximum will be 30 x 120 + 10 x120 = 4,8kVA, or 67% of the theoretical maximum.

The solution is an Autotransformer

By leaving the neutral of the split phase supply unused, and connecting an Autotransformer to create a new neutral, as shown in figure 1, any load unbalance is ‘absorbed’ by the Autotransformer. In case of a 30A supply, the load can be increased to 7,2kVA, and a 20A load unbalance will result in one leg supplying 40A, and the other leg 20A. The 20A difference will flow through the neutral and the windings of the Autotransformer. The current through both 120V wires of the split phase supply will be 30A.

Ground relay for use with Multi or Quattro Inverter/Chargers included

When operating in inverter mode, the neutral output of the inverter/charger must be connected to ground to guarantee proper functioning of a GFCI. In case of a split phase supply the neutral must be grounded. For this purpose a grounding relay is built in the autotransformer’s enclosure. The relay is controlled by the 230/240V Multi or Quattro. (The internal grounding relay in the 230/240V Multi or Quattro must be disabled)

Temperature protected

In case of overheating, the Autotransformer is disconnected from the supply. Reset is manual.

An alternative to stacked inverters

The alternative to stacking two 120V inverters to provide a 120/240V split phase supply is a 240V inverter with an additional Autotransformer. Two stacked 120V 3kVA inverters will supply up to 25A to each 120V leg. If the load on one leg is less than 25A, the maximum load on the other leg is still limited to 25A. One 240V 5kVA inverter with a 32A Autotransformer will supply up to 21A of balanced load to each 120V leg. Fewer loads on one leg will however result in more power being available on the other leg, with a maximum unbalance of 32A. Therefore the load can be up to 38,5A on one leg if the load is not more than 3,5A on the other leg (maximum unbalance: 38,5 – 3,5 = 35A). If load unbalance is to be expected, a lower power 240V inverter with autotransformer will therefore be preferable to the stacked inverter solution.

 

Dometic Harrier Brochures

Dometic Harrier Operation Manual

Specifications

SKU ITR000100001

Brand Victron

GTIN 8719076022404

Product Category Batteries Other


NOTE: see full product specifications & further product info in the section on this page.

Warranty

Warranty Period: 5 Years

Warranty Details: Please CLICK HERE for Warranty Information on this product

Delivery

  • We ship Australia-wide with national road express freight companies such as Star Track, TNT and Toll.
  • Small Items are sent with Australia Post via regular post.
  • Delivery times are generally 3-5 days from day of dispatch for major cities (sometimes quicker). Please allow longer for regional and remote areas.
  • Once your item(s) have been dispatched, we will provide you freight tracking information so you can track your delivery to your door.
  • Items are fully insured during the freight process.
  • Unfortunately we cannot deliver to PO Boxes.
  • For further details on our Delivery Process you can visit our Delivery Page HERE.

Reviews

Be The First To Review This Product!

Help other CARAVANRVCAMPING users shop smarter by writing reviews for products you have purchased.

Write a product review

Q & A


Do You Have Any Questions?